Feature

●[Reliable Materials] Industrial flame retardant ABS shell is impact and heat resistant, has a good comprehensive performance. All internal components adopt patch design, greatly increase the stability of the machine.
●[Multiple Protections] With soft start and stop function, protections of phase loss, constant torsion, load loss, overload, overcurrent, short circuit, overvoltage, undervoltage, overheat and stall, the VFD is very safe to use.
●[RS485 Interface] Standard communication protocol, users can read and write functional parameters, read status parameters, write control commands, etc. through upper computer. The converter is in the slave mode during communication.
●[Easy to Use] Humanized keyboard and digital display screen make the frequency inverter easier to operate. Unique design ensures strong heat dissipation performance and longer life.
●[Three Proof Paint Surface] Reduce the adhesion thickness of the paint surface and dust on the chip, ensure the reliability in harsh environment.


Description

Spec:
Item Type: Variable Frequency Drive
Material: Flame Retardant ABS
Power: 2.2KW
Applicable Motor Power: 2.2KW
Input: 1PH 220V 50/60Hz 13.5A
Output: 3PH 380V 0-300Hz 9A

How to Use:
1. For data frames in ASCII format, if frame length is even, frame will be discarded.2. The same function settings of multiple multi function input terminals will led to functional disorder, which should be avoided when users modify the multi function terminal functions through protocol.3. Some parameters have negative values, such as analog output torsion ?200.00 to +200.00. When the output torsion is 0, the data read by the communication is 0. When the input is ?0.01, the data read is 65535. When the input is ?200.00, the data read is 63536. When the data is negative, the maximum value is 65535, and the minimum value decreases in turn.

Package List:
1 x Variable Frequency Drive
1 x User Manual

Notice:
1. Before wiring, please confirm whether the input power supply is powered off.
2. The wiring operation shall be carried out by professional electrical engineering personnel.
3. The grounding terminal must be grounded.
4. After the emergency stop circuit wiring is completed, be sure to check whether the action is effective.
5. The output line of the frequency converter must not be connected with the housing, and the output line must not be short circuited.
6. Please confirm whether the voltage of main circuit power supply is consistent with the rated voltage of frequency converter.
7. Do not carry out voltage withstand test on the frequency converter.
8. Please connect the braking resistor according to the wiring diagram.
9. Do not connect the power cord to the output U, V, W terminals.
10. Do not connect the contactor to the output circuit.
11. Be sure to install the protective cover before powering on. When removing the cover, be sure to disconnect the power