Feature

●1.【Detects All Halogen Refrigerants】The professional refrigerant leak detector can detect all CFCs, HFCs and HCFCs refrigerants, such as R12, R11, R500, R503, R22, R123, R124, R502, R134a, R404a, R125, etc. Detect Blends such as AZ-50, HP62, MP39, etc; Detect Ethylene Oxide gas leaks; Detect SF-6 in high-voltage circuit breakers; Detect most gases containing Chlorine, Fluorine and Bromine; Detect cleaning agents used in dry cleaning applications; Detect Halon gases in fire extinguishing systems.
●2.【Power Indication and Battery Test Function】(1) After the leak detector is turned on, the leftmost LED is green, orange or red, indicating the battery power. (2) The battery test function is activated by pressing the battery test key. When pressed, the LED light will display the real voltage in red. The color position of the red LED light corresponds to the voltage. Except for the first LED light can display green, orange or red, the rest of the LED lights only display red.
●3.【Automatic Circuit/Reset Function】Upon initial power on, the refrigerant leak detector automatically sets itself to ignore the level of refrigerant present at the tip. Or press the reset button, and the LED lights will light up red for one second, which will make the circuit ignore the level of refrigerant present at the tip. Only a level, or concentration, greater than this will cause an alarm. Note: If the probe is turned on where there is already a leak, the leak will not be detected.
●4.【Six Levels of Sensitivity Adjustment】After the HVAC leak detector is turned on, the sensitivity is automatically set to level 5. Press the up/down key to adjust the sensitivity, short press or long press will have different adjustment effects. When the key is pressed, the LED light will display red, and the number of LED lights on indicates the level of sensitivity. NOTE: Each time the sensitivity level is increased or decreased, the relative sensitivity is doubled or halved.
●5.【6 Alarm Levels - Sound and Light Prompts】The refrigerant leak detector features 6 alarm levels, providing a clear indication of relative leak size and strength. The progressive indicators can be used to home-in on a leak, as the increasing alarm levels indicate that the source (highest concentration) is being approached. Each level is indicated by the number of red LED lights, the higher the level, the more red LED lights.
●6.【Advanced Microprocessor & 14-inch Probe & Rubber Handle】The refrigerant leak detector has an advanced microprocessor, which monitors the sensing tip and battery voltage levels 4000 times per second, compensating for even the most minor fluctuations in signal, which makes the leak detector work stably and reliably in almost all environments. The 14-inch elastic stainless steel shaping probe can be bent at any angle; the rubber handle is comfortable to hold.
●7.【Packing List and 3-Year Warranty】The refrigerant leak detector kit include a refrigerant leak detector, 2pcs replacement sensing tip protectors, 2pcs “C" cell batteries, an English manual, and a carrying case. We provide a 36-month free warranty and 24-hour friendly customer service to ensure your shopping experience. If you have any questions about this HVAC freon leak detector, please feel free to contact us and we will provide you with a satisfactory solution as soon as possible.


Description

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

DETECTING ALL HALOGEN REFRIGERANTS

  • HFC: R134a, R410A, R407C, R32, R417A, R404A, R507, R508A, R508B, R23, R152a etc.
  • HCFC: R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A etc.
  • CFC: R11, R12, R13, R502, R503 etc.
  • Blends: AZ-50, HP62, MP39, etc.
  • Ethylene Oxide gas leaks in hospital sterilizing equipment.
  • SF-6 in high-voltage circuit breakers.
  • Most gases contain Chlorine, Fluorine and Bromine.
  • Cleaning agents used in dry cleaning applications.
  • Halon gases in fire extinguishing systems.

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

ALARM INDICATIONS

  • The refrigerant leak detector features 6 alarm levels. This permits a clear indication of relative leak size and strength.
  • The progressive indicators can be used to home in on a leak; as the increasing alarm levels indicate that the source (highest concentration) is being approached.
  • Each level is indicated by the number of red LED lights, the higher the level, the more red LED lights.

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

OPERATION & OPERATION TIPS:

OPERATION:

  1. Switch the refrigerant leak detector on by pressing the ON/OFF key. The display will illuminate with the reset indication (Left LED green, all others Red) for 7 seconds.
  2. Verify the battery level by observing the constant power indicator.
  3. Upon turning on, the freon leak detector is set to sensitivity level 5. A rapid, but steady beep rate will be heard. If desired, the sensitivity can be adjusted by pressing the SENSITIVITY key.
  4. Begin searching for leaks. When refrigerant is detected, the audible tone will change to a siren type sound, distinctly different from the base beep rate. Additionally, the visual indicators will light progressively.
  5. Sensitivity can be adjusted at any time during operation by using the SENSITIVITY key. This adjustment will not interrupt detection.
  6. If a full alarm occurs before the leak is pinpointed, press the RESET key to reset the circuit to zero.

OPERATION TIPS:

  1. Turn up the sensitivity only if no leaks are detected. Only turn down the sensitivity if resetting the refrigerant leak detector doesnt allow you to "home-in" the leak
  2. In areas that are heavily contaminated with gas, the refrigerant leak detector may be reset to block out ambient concentrations of gas. The probe should not be moved while the unit is being reset. The HVAC leak detector can be reset as many times as needed.
  3. In windy areas, even a large leak can be difficult to find. Under these conditions, it is best to shield the potential leak area.
  4. Be aware that the freon leak detector may alarm if the sensing tip comes in contact with moisture and solvents. Therefore, avoid contact with these when leak checking.

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

To Replace the Tip

Make sure the refrigerant leak detector is turned off, unscrew the old tip counterclockwise, and screw on the spare tip in the carrying case clockwise.

Tactile Keypad Controls

LED indicator shows a progressive and wide-ranging leak size indication, communicates the sensitivity level, and provides a true voltage indication of battery power level. Six levels of sensitivity provide an increase of 32 times from level 1 to level 6.

Operates On 2 "C"-cell Batteries

Remove the battery compartment door located on the bottom of the refrigerant leak detector. Install batteries, Positive Polarity towards the outside.

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

SPECIFICATIONS:

Power Supply: 3V DC, two "C" cell Alkaline batteries

Maximum Sensitivity: Certified for R12, R22, R134a @ 0.5 oz/yr(14gr/yr)

Ultimate Sensitivity: Less than 0.1 oz/r(3gr/yr) for all Halogen based refrigerans

Sensing Tip Life: About 20 hours

Operating temperature: 30℉-125℉(0-52℃)

Battery Life: About 30 hours of normal use

Duty Cycle: Continuous, no limitation

Response Time: Instantaneous

Reset Time: one second

Warm-Up Time: About 7 seconds

Unit Weight: 1.01 Ibs (560 grams)

Unit Dimensions: 9.2" x 2.8" x 1.95"(24.2cm x 71.5cm x 50cm)

Fixed Probe Length: 14inch/35.5cm

PACKING LIST

Refrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector FinderRefrigerant Leak Detector HVAC Freon AC Leak Detector Kit Halogen Gas Leak Detector Finder

PRODUCT MAINTENANCE

WARNING:

The refrigerant leak detector must be turned off before replacing the sensing tip.

Keep the Sensing Tip Clean:

prevent dust, moisture and grease build-up by utilizing the provided tip protector. Never use the refrigerant leak detector HVAC tool without the protector in place. Before using the unit always inspect the tip and protector to see that they are free of dirt and /or grease.

Cleaning Method:

1. remove the protector by grasping and pulling off the tip

2. clean protector with a shop towel and/or compressed air

3. If the tip is dirty it can be cleaned by immersing it in a mild solvent, such as alcohol, for a few seconds, and then using compressed air and/or a shop towel to clean.

NOTE: Never use solve nets such as gasoline, turpentine, mineral spirits, etc... as these will leave a detectable residue and desensitize your HVAC leak detector.

Sensing Tip Replacement:

Tip longevity is directly related to the conditions and frequency of use. The tip should be replaced whenever the alarm sounds or becomes erratic, in a clean, pure-air environment.

Digital Manifold Gauge Set Terminal Removal Tool Kit Exhaust Back Pressure Tester Kit Multimeter Test Leads Kit 92 Pieces Thread Repair Kit 42Pcs Thread Chaser Set Rethreading Kit Fuel Injector Cleaner Tool
Digital Manifold Gauge Set 23Pcs Terminal Removal Tool Kit Exhaust Back Pressure Tester Kit 92Pcs Multimeter Test Leads Kit 42Pcs Thread Chaser Set Fuel Injector Cleaner Tool
Customer Reviews
4.1 out of 5 stars
89
3.7 out of 5 stars
25
4.6 out of 5 stars
169
4.5 out of 5 stars
77
4.3 out of 5 stars
148
4.2 out of 5 stars
96
Price $159.99 $35.99 $39.99 $89.99 $39.99 $98.99
FEATURES The gauge has a built-in 93 refrigerant pressure-evaporating temperature database. The gauge has the double pressure test, dual temperature test, digital readout, multi-unit switching, and multi-mode function. This kit easily releases terminals from the plastic connector housings on every electrical connection on your vehicle or computer. It eliminates damage to wires or terminal blocks, making it safer and more efficient. Helps you quickly and accurately determine the condition of the vehicles exhaust system, which can prevent sluggish engine performance, reduced acceleration, and excessive heat. This kit can be used with any multimeter and oscilloscope probe extension cables for diagnosing, testing and repairing complex vehicle circuits. It can also troubleshoot sensors, actuators and electronic circuits. The kit has the most common sizes in UNC, UNF, and metric. Cleans internal and external threads. The thread chaser set is great for cleaning up crusty, rusted and damaged threads. This tool can clean the entire fuel system, including the throttle valve, fuel nozzle, combustion chamber, fuel injector, intake system and three-way catalytic converter.