Feature(may vary by option.)

●Welcome to inquire

[Default]





Description

Package List:
1 * External S Meter Display Meters for Yaesu FT-857/FT-897
FT-857D& FT897D external header display setting method
Receive Display
1. press (FUNC) key to enter the setup , enable the extended .
2. rotate (SELECT) to call up the setup item No-061(MTR ARX SEL).
3. rotate (DIAL) to select an external instrument display:
-SIG: the input signal strength display
-CTR: Discriminator Center Meter
-VLT: battery voltage
-N / A: blank
-FS: buckle in the instrument 1mA full scale output signal calibration standard external instruments
-OFF: Turn off the meter.
4. press (FUNC) button to save the and exit the setup .
Emission Display
1. press (FUNC) key to enter the setup , enable the extended .
2. rotate (SELECT) to call up the setup item No-061 (MTR ARX SEL).
3. rotate (DIAL) to select an external instrument display:
-PWR: transmit power display
-ALC: Automatic Level Control voltage display
-MOD: Modulation Level Display
-SWR: SWR display
-VLT: Display Supply Voltage
-N / A: blank
-OFF: Turn off the meter.
Calibration method is as follows
1. press (FUNC) key to enter the setup , enable the extended .
2. rotate (SELECT) to call up the setup item No-060 (MTR ARX SEL).
3. rotate (DIAL) to select FS.
4. with a small flathead screwdriver to adjust the calibration adjustment hole rear, so the header pointer to full scale.
5. the calibration is complete!
Note:
The instrument has been calibrated delivery, but do not preclude the bumps transit results in a static pointer is not zero, in this case the instrument can be adjusted at the mask-side self-zeroing screws appear black.