Feature

●The temperature measurement accessories use accurate formulas, real materials, composed of more than 100 ingredients, similar to ceramic ingredients, to ensure more accurate temperature measurement.
●Most measurement methods are limited by time and space. Temperature measuring accessories can effectively solve this problem and help you measure temperature accurately and conveniently.
●For example, thermocouples and temperature measuring rings, thermocouples can only measure the radiant heat of the kiln, but cannot measure the heat transfer of the kiln, and cannot truly reflect the temperature of the product.
●The temperature measuring ring is extremely easy to be limited by time. The temperature after combustion is measured and calculated by a scale, but the product has been qualitative.
●It is widely used to determine the sintering temperature of refractory materials, chemical materials, abrasive materials, magnetic materials, ceramics and other materials in the sintering process.


Description

Specification:
Condition: 100% Brand New
Item Type: Pyrometric ConeModel:5#
Material: Clay
Color: As Pictures ShownSoftening Temperature: 1230℃
Weight: Approx. 235g
Size: Approx. 6.5x1cm/2.56x0.39inch

Package List:
1 x Box of Ceramic Kiln Temperature Measuring Cone

Usage:
1. Three adjacent temperature-measuring cones were taken as a group, the lower cone was the guide cone, the higher cone was the backup cone, and the middle cone was the firing cone
2. Insert the base side by side about 1cm so that the right angled edges are perpendicular to the ground and tilted 80°
3. After drying, it is put in the kiln for easy observation. The better effect is that the bending Angle of the temperature measuring cone should be greater than 20° and less than 100°
4. The temperature measuring cone can also be placed at the bottom, middle and top to measure the temperature difference in different positions inside the furnace
5. The softening temperature of the temperature measuring cone will be deviated due to different heating methods, so the temperature rise must be slow and 10° per minute is appropriate
6. Refractory mud base should be placed flat; In order to master the sintering temperature more accurately, several groups of temperature measuring cones should be selected and several observation points should be set up at the same time
7. The base can be kneaded by mud, and then the temperature measuring cone is vertically inserted into the ground, and then tilted by 80°