Feature(may vary by option.)

●【Widely Used Digital Manometer】Professional manometer gas pressure tester is specially used for gas measurement and calibration, gas pressure system troubleshooting, laboratory testing, maintenance and installation of blowers, clean rooms, boilers and other gas appliances. Manometer hvac is widely used in pressure detection of natural gas pipelines and air-conditioning refrigeration ventilation systems, gas, liquid and production industrial equipment pressure detection, etc.
●【Single/Dual Channel Test & 12 Pressure Units】Manometer is designed to measure static and differential pressure from 2 ports in air and gas systems. Single channel can quickly measure the current detection pressure value (relative to the current atmospheric pressure), while dual channel can simultaneously detect the pressure difference between 2 ports.It supports 12 pressure units, directly output data without conversion: mmHg, inHg, ftH2O, cmH2O, inH2O, Pa, KPa, mbar, bar, psi, Kgcm² and ozin²
●【14.5Psi Wide Measuring Range & High Accuracy & Fast Response】This upgraded differential manometer gauge expands the measuring range to ±100kPa/±14.5Psi. Our gas pressure manometer comes with an advanced pressure sensor with a quick response of 0.5 seconds. Manometer hvac is also equipped with a high-precision ADC with an accuracy of ±0.3% FSO (25°C) and a resolution of up to 0.001Psi, so it can measure both small differential pressure and airflow pressure. Maximum pressure value: 100kPa.
●【Strong Magnet On Back & LCD Backlight Display】The back of our digital manometer hvac is specially designed with a strong magnet, which can be easily attached to various magnetic surfaces, freeing your hands. The gas manometer hvac is equipped with a large LCD screen with backlight, the data is clear and easy to read, allowing you to read it easily even in poor light conditions.
●【Data Record & Data Hold & 100 Groups Data Storage】The manometer gas pressure tester can record pressure values over a period of time and generates maximum and minimum values. And digital manometer hvac has data hold function and can store 100 sets of measured pressure values, which is convenient for you to check.
●【Auto Power Off & Low Battery Prompt & Portable Carrying Bag】After about 15 minutes of power on, if the manometer hvac is in a state of no operation, it will automatically shut down to help you save power. Digital manometer also has low battery prompt function. It is powered by a 9V battery(included). Gas pressure manometer hvac comes with a carrying bag for easy carrying and storage.
●【What You Get】1pc Main unit, 1pc Barb metal connector (thread size: 1/8 inch), 1pc Tapered adapter, 2pcs* 9.8inch hoses (OD: 1.57*2.36inch), 2pcs* 9.8inch hoses (OD: 1.97*3.15inch), 1pcs* 59inch hoses (OD: 1.97*3.15inch)

[±241.3Kpa]




[±100Kpa]





Description

11

This manometer gas pressure tester can be extensively used in natural gas pipelines, air conditioning and refrigeration ventilation systems, mechanical hydraulics, plastic molding, ceramic products manufacturing, biopharmaceutical molding, mining pressure testing, petrochemical Industrial smelting, gas, liquid and production industrial equipment pressure detection, liquid level detection, Laboratory calibration, medical environment micro-pressure testing, etc.

22

Specifications:

Measuring Range: ±100kPa

Accuracy: ± 0.3% FSO (at 25℃)

Repeatability: ± 0.2%(Max ± 0.5% FSO)

Linearity/Hysteresis: ± 0.29%FSO(25℃)

Measurement Rate: 0.5 seconds

Data Storage: 100 groups

Maximum Pressure: 100kPa

Power Supply: 1pc 9V battery (included)

Exceed the positive pressure range display: Err0

Exceed the negative pressure range display: Err1

Indoor temperature measurement: Optional ℃/℉ unit

Working Temperature: 0~50℃ (32~122℉ ), Storage Temperature: -10~60℃ (14~140℉ )

Automatic Shut-down: After about 15 minutes without any operation

Dimensions: 5.9*2.83*1.37inch, Weight: 1 Pound

33
44
55

Operation Instruction of Buttons:

1. POWER button

a. Short press to turn on.

b. Short press to turn on/off the backlight in the power-on state.

c. Press and hold to shut down (automatically shut down after 15 minutes of no operation).

2. ℃/℉button

a. Short press to store the current measured pressure value ( up to 100 groups).

b. Long press to exit the storage mode.

c. Long press for more than 2 seconds to switch the temperature unit.

3. HOLD button

a. Short press to lock and hold the current data value.

b. Long press for more than 2 seconds to clear the drift data (Please press and hold this button if the data is not reset before measurement).

77

4. UNITS button

a. Short press to switch between up to 12 pressure units.

b. Long press for more than 2 seconds to clear the stored data.

5. DIF button

a. Short press to go up to view stored data.

b. Long press for more than 2 seconds to enter the P1 and P2 dual-channel differential pressure mode.

c. In DIF mode, press and hold for more than 2 seconds to exit the differential pressure mode.

6、MAX button

a. Short press to go up to view stored data.

b. Long press for more than 2 seconds to enter the maximum and minimum mode.

c. Long press for another more 2 seconds to return to the normal measurement mode.

66

Packing List:

1pc * Main unit

1pc * Barb metal connector (thread size: 1/8 inch)

1pc * Tapered joint

2pcs * 9.8inch hoses (OD: 1.57*2.36inch)

2pcs * 9.8inch hoses (OD: 1.97*3.15inch)

1pc * 59inch hoses (OD: 1.97*3.15inch)

1pc * 9V battery

1pc * Manual

1pc * Carrying Bag

Whats in the box

  • Connector