Feature

●Dual Output: The control module adopts dual relay outputs, which can control temperature and humidity, meeting various needs.
●Automatic Recognition: When the start temperature is greater than the stop temperature, enter cooling mode C; When the start temperature is lower than the stop temperature, enter heating mode H.
●Cooling Mode: When detection temperature is ≥ start temperature, the cooling equipment starts working; When detection temperature is ≤ stop temperature, the cooling equipment stops working.
●With Indicator Light: The temperature and humidity controller is designed with indicator light and the working status is clear and intuitive.
●Heating Mode: When detection temperature is ≤ start temperature, the heating equipment starts working; When detection temperature is ≥ stop temperature, the heating equipment stops working.


Description

1. Dual Output: The control module adopts dual relay outputs, which can control temperature and humidity, meeting various needs.
2. Automatic Recognition: When the start temperature is greater than the stop temperature, enter cooling mode C; When the start temperature is lower than the stop temperature, enter heating mode H.
3. Cooling Mode: When detection temperature is ≥ start temperature, the cooling equipment starts working; When detection temperature is ≤ stop temperature, the cooling equipment stops working.
4. Heating Mode: When detection temperature is ≤ start temperature, the heating equipment starts working; When detection temperature is ≥ stop temperature, the heating equipment stops working.
5. With Indicator Light: The temperature and humidity controller is designed with indicator light and the working status is clear and intuitive.

Specification:
Item Type: Temperature Humidity Controller
Material: ABS
Model: XY WTH1
Temperature Measurement Range: -20℃ to 60℃
Humidity Range: 00% to 100%
Control Accuracy: 0.1℃ 0.1%
Detection Probe: Integrated sensor
Output Type: Relay output
Output Capacity: Up to 10A
Temperature Correction Function OFE (-10.0℃ to 10.0℃):
If the system works for a long time, there may be deviations. By using this function to correct, the actual temperature=measured temperature+calibration value;
How to set the start and stop temperature:
1. In the running interface, press and hold the TM+ key for more than 3 seconds to enter the startup temperature setting interface. Testing can be done by modifying parameters using the TM+ TM- key. After the parameter modification is completed, wait for 6 seconds to automatically exit and save.
2. In the running interface, press and hold the TM- key for more than 3 seconds to enter the stop temperature setting interface. Testing can be done by modifying parameters through the TM+ TM- key. After the parameter modification