Feature

●Generator Controller is an outstanding compact control module that provides a comprehensive range of features for single-set applications.
●Generator Set Start & Protect: Used to start and protect a single generator set, realize the manual and remote start and stop of the generator set, data measurement, alarm indication, shutdown protection, etc.
●Light touch button operation to achieve precise measurement of various parameters, all configuration parameters can be adjusted from the front panel of the controller
●Reliable Operation Easy Installation: generator set controller has the advantages of simple operation, reliable operation, compact structure, and convenient installation
●embedded installation method, small size and easy installation


Description

MGC120petrol generator set controller
The MGC120 petrol generator set controller is an AMF module that can be used in the automation and monitoring system of a single gasoline generator set. Through data measurement, the functions of automatic start/stop, alarm protection, ATS switching control of the generator set are realized. The controller adopts LED digital tube display and touches the button operation. Most of the parameters can be adjusted from the front panel of the controller. Through the LINK interface, all parameters can be adjusted from the PC. MGC120 gasoline generator set controller has the advantages of simple operation, reliable operation, compact structure and convenient installation. It can be widely used in the automation system of various gasoline generator sets.
2. PERFORMANCE AND CHARACTERS
--Able to collect single phase voltage of Mains and generator, which is suitable for 50Hz/60Hz AC system;
--Switchable display parameters:
Mains voltage (V)
Generator voltage (V)
Engine cylinder temperature ()
Generator frequency (Hz)
Battery voltage (V)
Accumulated running time(H)
--Equipped with Mains electricity monitoring function and AMF function;
--Protection function for generator under/over volt, under/over frequency, low oil pressure, and start failure protection functions; when they occur, LED indicates alarm types, and controller
conducts shutdown protection;
--Using stepper motor and programmable outputs to control air flap;
--Speed signals derive from ignition coil primary (diode needs to be in series);
--Able to choose from three crank disconnection conditions (generator frequency, speed, and speed + gen frequency);
--Equipped with 3 stationary relay outputs (fuel output, start output and ignition control);
--Equipped with 2 programmable transistor outputs, which can be set as common alarm output, ETS control, idle speed control, preheating control, GCB close output, MCB cl