[500ft Black]
[500ft White]
|
|
|
---|---|---|
18 GaugeDrive speakers up to 32 feet @ 8 ohms or 16 feet @ 4 ohms. Conductor resistance ≤ 21.9 ohms/km. Alternatives:
|
2 Conductor UnshieldedUse for single channel speaker-level audio, low voltage lighting, or any low voltage application that requires 2 conductors. Alternatives:
|
Plenum RatedCL3P rated for installation in walls, risers (between floors), and plenums in both residential and commercial applications. Alternatives:
|
Copper is the industry standard wiring material for a reason. Compared to aluminum, its higher conductivity translates into improved signal & power transmission and more performance headroom at a given length. Coppers lower electrical resistance means that it generates less heat, which is a crucial factor in preventing the degradation and breakdown of conductor insulation. Finally, copper is more durable than aluminum and wont break while being flexed or terminated.
|
|
|
---|---|---|
Patented Payout SystemCables packaged in our pull box feature a proprietary winding pattern and huge 4" payout hole which ensure the cable pays out straight, without kinks or snags. |
Rugged Pull BoxOur pull box is made of thick, double walled cardboard and features a water resistant coating & reinforced handles so it stays intact on the most demanding job sites. |
Jacket MarkingThe jacket printing on our cables shows the part number, all relevant fire safety information, as well as foot markers indicating both how much wire has been used and how much is remaining. |
Rigorous adherence to the UL 13 safety standard governing the construction of power-limited circuit cables, including acceptable materials and minimum thickness for conductors, insulation, shielding, and outer jacket; as well as tests for conductor continuity & resistance, insulation resistance, cold bending, and (when applicable) sunlight resistance, crushing, and water absorption.
UL Listed with a Plenum (CL3P) fire safety rating for installation in walls, risers (between floors), and plenums in both residential and commercial applications in compliance with the National Electrical Code (NEC). UL is the most stringent flame testing laboratory, which makes UL Listed a mark of quality and is why weve chosen UL to flame test our cables.
Conductor Gauge & Material | 18AWG Bare Copper |
Conductor Count | 2 |
Conductor Stranding | 16/0.251mm |
Conductor Max Resistance | 21.9 ohms/km @ 20°C |
Insulation Colors | Red, Black |
Insulation Material | Low-smoke Flame Retardant Polyvinyl Chloride (LSFRPVC) |
Insulation Outer Diameter | 1.7mm |
Jacket Material | Low-smoke Flame Retardant Polyvinyl Chloride (LSFRPVC) |
Jacket Outer Diameter | 4.2mm |
Shielded? | No |
Fire Rating | CL3P (Plenum) |
Direct Burial Rated? | No |
UV Rated? | No |
Voltage Rating | 300V |
Temperature Rating | 75°C |
Additional Specifications | See PDF data sheet below for full specifications |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
---|---|---|---|---|---|---|
18/2 In-Wall | 18/2 In-Wall & Direct Burial | 18/2 Plenum | 18/4 Plenum | 16/2 Plenum | 14/2 Plenum | |
Conductors | 18AWG x 2 | 18AWG x 2 | 18AWG x 2 | 18AWG x 4 | 16AWG x 2 | 14AWG x 2 |
Strand Count | 16 | 42 | 16 | 16 | 26 | 41 |
Speaker Distance (8 Ohm) | ≤ 32ft | ≤ 32ft | ≤ 32ft | ≤ 32ft | ≤ 48ft | ≤ 80ft |
Resistance (20°C) | 21.9 ohms/km | 21.9 ohms/km | 21.9 ohms/km | 21.9 ohms/km | 13.7 ohms/km | 8.6 ohms/km |
Shielded | No | No | No | No | No | No |
Fire Rating | CL3 ? General Purpose | CL3 ? General Purpose | CL3P ? Plenum | CL3P ? Plenum | CL3P ? Plenum | CL3P ? Plenum |
UV Rated | No | No | No | No | No | No |
Burial Rated | No | Yes | No | No | No | No |
Residential Applications | Walls & Risers | Walls & Risers | Walls, Risers, & Plenums | Walls, Risers, & Plenums | Walls, Risers, & Plenums | Walls, Risers, & Plenums |
Commercial Applications | Walls | Walls | Walls, Risers, & Plenums | Walls, Risers, & Plenums | Walls, Risers, & Plenums | Walls, Risers, & Plenums |