●Basic Values: This surge protection device has Uc of 420V, Imax of 60KA, In of 30KA, and an operating ambient temperature of -40°C to +80°C.
●Return Normal: When the surge voltage through the protection device, and after the overvoltage disappears the protection device revert to a high resistance state, so as not to affect the normal operation of the grid.
●Working Principle: Under normal conditions the protection device is in a high resistance state, when the grid due to thunder or other reasons for dealing with surge overvoltage, the surge protector will be immediately in the nanosecond time quickly conductive, the surge overvoltage into the earth, thus protecting the power equipment on the grid.
●Usage Scenario: In the 3 phase and 4 wire system, the 3 phase wires and a neutral wire to ground are connected between the protection device and being suitable for home, farm, office building and so on.
●Limit Transient: Surge protection device is mainly used to limit the transient overvoltage amplitude, absorption, consumption or discharge of inrush current energy. Make in the overvoltage category of higher situations, can make the protected electrical components from an overvoltage category to another lower overvoltage.


Description

Feature:
1. Basic Values: This surge protection device has Uc of 420V, Imax of 60KA, In of 30KA, and an operating ambient temperature of -40°C to +80°C.
2. Working Principle: Under normal conditions the protection device is in a high resistance state, when the grid due to thunder or other reasons for dealing with surge overvoltage, the surge protector will be immediately in the nanosecond time quickly conductive, the surge overvoltage into the earth, thus protecting the power equipment on the grid.
3. Return Normal: When the surge voltage through the protection device, and after the overvoltage disappears the protection device revert to a high resistance state, so as not to affect the normal operation of the grid.
4. Limit Transient: Surge protection device is mainly used to limit the transient overvoltage amplitude, absorption, consumption or discharge of inrush current energy. Make in the overvoltage category of higher situations, can make the protected electrical components from an overvoltage category to another lower overvoltage.
5. Usage Scenario: In the 3 phase and 4 wire system, the 3 phase wires and a neutral wire to ground are connected between the protection device and being suitable for home, farm, office building and so on.

Specification:
Item Type: Surge Protective Device
Material: Flame retardant PC
Installation: 35mm(1.4in) Electrical Rail
Uc: 420V
Imax: 60KA
In: 30KA
Up: ≤2.2KV
Operating Ambient Temperature: -40℃ to +80℃

How to Use:
1. Connecting wires should be used with the power line capacity of the same or greater than the power line wire, the total length should be controlled within 0.5 meters, the shorter the length of the wire the better.
2. In the front of the surge protector must be connected in series with the corresponding air switch or fuse.
3. must be disconnected from the power supply when installed.
4. Surge protector fault judgment.
4.1. The modules