[25mm 0.22um]
[25mm 0.45um]
Nylon membrane has high strong mechanical strength, chemical stability, can be tolerated by most organic solvents, extremely low in extractables, good thermal stability (up to 50°C), natural hydrophilic and the majority of water solution filter characteristics. It more often applied to the common organic solvent HPLC mobile phase filtering.
Nylon membrane filters are hydrophilic, flexible, tear-resistant, and autoclavable. They are resistant to a range of organic solvents and suitable for use with high pH samples. Nylon binds proteins. Unsuitable for acidic solutions. pH range ~3-14.
Filter Medium | Nylon |
PH range | ~3-14 |
Max Operating Temperature | 130℃ |
Max Operating Pressure | 87psi |
Volume Area | < 100ml |
Filtration Area | 4.15cm² |
Wettability | Hydrophilic |
Membrane Pore Size | 0.22um / 0.45um |
Membrane Diameter | 25mm |
Connections(Inlet/Outlet) | Female Luer Lock inlet and Male Luer slip outlet |
![]() Click to Purchase | ![]() Click to Purchase | ![]() Click to Purchase | ![]() Click to Purchase | |
Volume
| 2ML | 5ML | 10ML | 20ML |
Material
| Plastic | Plastic | Plastic | Plastic |
Needle
| ? | ? | ? | ? |
Connector
| Luer slip | Luer slip | Luer slip | Luer slip |
Packaging