Feature

●Five-digit big LCD, super low power consumption, large and clear indication.
●Press Counting/Pause key (Pause) to stop counting, after 0-30 sec, LCD indication will be automatically off and in standby state. Press the Counting/Pause key again to turn on the indication and continue to count. Maximum counting speed: 20 times per second.
●Use magnetic induction, easy to install and precise counting. Anti-vibration, efficiently make sure the stable and reliable system operation.
●Use the common AA battery, free from external power supply.
●Free from mechanical abrasion, safe work, long lifespan.


Description

Specifications:
Power: 1.5V-AA battery(Not included)
Available ambient temperature: -5~40°C(23-104℉)
Distance within the magnetic induction: about 5-10mm
Hole size: Approx.63*35mm/2.5*1.4in
Application Method:
1. Start counting: connect the magnetic control induction switch to the counting terminal, according to the requirements of actual operation, flexibly assemble the magnetic induction switch and magnet on the appropriate positions of device, and then do counting once, meanwhile, make the magnet approach and leave the magnetic control induction switch once.
2. During operation, make the magnet follow device with distance from the magnetic switch within 0.5-1 cm, then move the magnet to lengthen distance to be 3-5cm, next, start count as 1, repeat the procedures, and accumulate count, like: 0, 1, 2, 3, 4, 5, 6 ......(Note: start count when the magnet moves away). During assembly, please adjust the positions of magnet and induction switch, as well as their distance.
3.Pause counting: Press the Counting/Pause (Pause) key to pause counting. According to the running states of counter, the counter LCD indication will be off within 0-30 seconds and into standby state (power consumption nearly closes to 0); Press the Pause key again to turn on the LCD indicator and continue to count.
4.Reset: directly press the Reset button; or additionally connect one Reset button (need to buy by end user) to the reset terminal, and then press it to reset the device. Note: during reset, no matter the counter is in startup state or standby state (LCD has no indication), data will be erased and the LCD indication is 00000.
5. The counting signal and reset signal only can be inputted with contact signal, other power signals are not allowed.
6. The operation temperature of magnet should be within 70 degree, over high temperature will cause magnetism lose, further to invalidate induction.