Feature

●Space Save: Equipped with stainless steel fixed bracket, easy to install and use. Small and compact size, light weight. Minimum installation space is required.
●Stainless Steel Material: The swimming pool heat exchanger is made of high grade anti corrosion stainless steel, anti rust and salt water resistance, durable.
●Constant Temperature: It is heated by water, and the cold water is turned into hot water by heat energy, which is heated circularly. It is suitable for the simultaneous use of solar panels (shipped without solar panels).
●Application: The heat recovery pool heater is suitable for swimming pools, spas, hot tubs, solar, hydraulic heating, oil cooling, heat recovery, snow melting, etc.
●Maximum Heat Exchange: Specially designed built in flow limiter aims to minimize the pressure loss in the heating system and ensure maximum heat exchange.


Description

Specification:
Item Type: Pool Heat Exchanger
Material: Stainless Steel
Weight: Approx. 2837g/100.07oz
Size: 34.2x15.7cm/13.46x6.18in
Specifications: 40KW
Note: Does not contain electricity
Side Thread: Female Thread 45mm/1.77in
Front and Rear Thread: Female Thread 32mm/1.26in
Maximum Operating Temperature: 230℉ (110℃)
Type of Heat Exchanger: MF 135
Application Scenario: swimming pool, hot spring, hot tub
Swimming Pool Area: 12000 Gallon, Temperature required to rise 1 ℉/h: 100098 btu/h; Temperature required to rise 2 ℉/h: 100098
Swimming Pool Area: 14000 Gallon, Temperature required to rise 1 ℉/h: 116781 btu/h; Temperature required to rise 2 ℉/h: 133464
Swimming Pool Area: 16000 Gallon, Temperature required to rise 1 ℉/h: 133464 btu/h

How to Use:
1. Generally, the temperature rise of the swimming pool that is open for a long time in summer is 1 ℉ per hour (1 ℉=0, 56 ℃), while the temperature rise of the swimming pool that is only used for a short time is 20 ℉ per hour; 2. Calculate the volume of the pool (in gallons: 1 cubic meter=264,2 gallons) 3. Check the following table, select the model of the heat exchanger according to the volume of the pool water and the required heating rate, and ensure that the output power of the boiler meets the requirements in the table; 4. Calculate the heat loss rate to ensure that the output power of the boiler is greater than the heat loss rate calculated by the following formula: heat loss rate (btu/hour)=233,28 x The area of the swimming pool (square meter) x (the required temperature of the pool water ℃ ? the lowest average external temperature ℃ during use) Note: The water temperature of the swimming pool is generally required to be 26 ℃.

Package List:
4 x Part
1 x Heat Exchanger
1 x Instruction