[DC12V]
Item Description:
Part Name :5101PM-2 DC12.0V pump
P/N:
1.:
This specification is applicable to Micro air Pump XIN5101PM-2 DC12.0V .
2-1
The standard of enviro nt is the ambient temperature of 20℃ and relativehumidity of 65%RH.If no disputes occur,the can be conducted under the blow circumstance:the ambient temperature of 5-45℃and relative humidity of 30~80% RH.
2-2 position:
Horizontal
2-3 Load:
air
3. Function:
3-1 Rated voltage:DC12.0V
3-2 Operating voltage : DC9.0V~15.0V
3-3 Current
Current with load: <3000mA
During pumping from 0 to -90Kpa aDC12.0V voltage.
3-4 Noise:Less than 55dB(FIG 1)
Put a sponge of 5cm under the pump and distance to noise meter from 30cm.
and while pressurizing from 0 to -90Kpa to noise value at 12.0V voltage(FIG1)
3-6 Pressure :More than 400Kpa(3000mmHg)
The pressur value is while the pump s the i ation at DC 12.0V voltage
3-7 Vacumm:≤-90Kpa flow 15L/MIN( connection)
?空度 Vacumm:≤-80Kpa flow 18L/MMIN(parallel)
3-8 Operation temperature range:
The temperature have to be between 5℃ and 50℃ and humidity must is between 30%and 80%RH to function the pump well.
3-9Preservation temperature range:
4. Reliability :
4-1 Low-temperature characteristic:
Putting the pump in the temperature at negative 20℃ for48 hours;then taking it out and putting it in a room temperature at 20℃±5℃ for two hours.Under this circumstance,running through 3.3 3.4 3.5 3.6 3.7 and finding out that the pump still peorms well.
4-2 High-temperature characteristic:
Putting the pump in the temperature at 60℃ for 48 hours;then taking it out and
putting it in a room temp