Feature

●Moudbus RTU output, 360 degrees (one turn)
●12 Bit Resolution 4096
●60mm outer dia, Clamping Flange-Shaft 10mm
●External resetting line to set the default location, easy installation, no need to find ZERO.
●10-30VDC Wide working voltage ,low power consumption


Description

CAS60R*** Clamping Flange-solid shaft Encoders

CAS60RCAS60R

CAS60CAS60

CAS60CAS60

  • Motion control applications ? ranging from factory automation to control systems for mobile machines ? require precise, real-time information about the physical location of mechanical equipment.
  • Absolute rotary encoders can provide precise and unambiguous measurements without losing track of their position due to a temporary loss of instrument power. Singleturn encoders are providing a measurement range of 360 degrees (one turn).
  • When the shaft of the encoder is turned by more than 360 degrees, output characteristics in subsequent turns will be equal to the first turn.
  • Examples: output@361 degrees = output@1 degree, output@720 degrees = output@360 degrees.
  • Power supply: 10-30V DC
  • Shaft diameter: 10mm
  • Body diameter: 60mm
  • Cable length: 1 meter
  • Resolution: 12 bits
  • Output: Parallel /SSI/RS485/Modbus RTU/4-20mA output, can be connected to a variety of devices
  • Maximum shaft speed: 2400 rpm
  • Protection: housing IP67,shaft IP65
  • Current consumption: ~50 mA
  • Weight: about 0.3kg
  • Operating temperature: -25°C to +80°C
  • Storage temperature: -40°C to +80°C
  • Shape features:metal sealed housing, sealed double-bearing structure

CAS60R series Absolute encoder Selection table

CAS60R12E10PB?型表CAS60R12E10PB?型表

Note:

* The encoder is a precision instrument, do not knock or bump encoders, gently, carefully use;

* Guaranteed encoder supply in the range 10-30Vdc and do isolation to prevent large-scale electric power grid to start the encoder produces shock;

* In the environment of strong electromagnetic interference, the signal line is best to use a dedicated line, such as double-shielded twisted pair cable can be ordered from the Company;

* Encoder signal line should be well grounded: close, both ends of the cable shielding should be grounded within two meters; greater distance encoder grounded metal enclosure, the encoder comes with cable shielding vacant, signal extension cable shielding in signal receiving end single-grounded; If the signal cable longer or outdoor use, signal cables should put metal iron pipe and metal pipe at both ends of the ground to use;

* Encoder protection class IP65, waterproof to use, but do not flooding the encoder shaft.