Feature

●RS485 Communication: The inverter with RS485 communication, and built in brake unit can be externally connected to the brake resistor emergency stop brake.
●Full SMD Design: All internal components of the inverter are designed with SMD, which greatly increases the stability of the machine.
●ABS Shell: The inverter shell is made of industrial flame retardant ABS plastic, which is highly impact resistant, highly heat resistant, flame retardant and has good overall performance.
●Powerful Function: This inverter adopts cutting edge motherboard, intelligent and efficient, with extremely strong protection performance and complete functions.
●Quiet Heat Dissipation: The inverter has a large heat sink and with a small fan. The small fan ensures low noise while assisting good heat dissipation.


Description

Specification:
Item Type: Universal Vector VFD
Material: ABS
Storage Temperature: -25℃-55℃
Input Voltage: Three phase 380-440V AC
Output Voltage: Three phase 0-440V AC
Output Current: 4.1A
Braking Resistor:
Braking Resistor Power: 300W
Braking Resistor Resistance Value: 400Ω

How to Use:
1. Before wiring, please make sure that the input power is in the power off state.
2. For wiring operation, please ask professional electrical engineering personnel to do it.
3. Grounding terminal, please make sure to ground.
4. After wiring the emergency stop circuit, make sure to check whether the action is effective.
5. The output line of the inverter must not be connected to the shell, and the output line must not be short circuited.
6. Please make sure the voltage of the AC main circuit power supply is the same as the rated voltage of the inverter.
7. Please do not perform voltage withstand test on the inverter.
8. Please connect the braking resistor according to the wiring diagram.
9. Do not connect the power cable to the output U, V, W terminals.
10. Do not connect the contactor to the output circuit.
11. Be sure to install the protective cover before power is applied. When removing the cover, be sure to disconnect the power supply.
12. Do not use the inverter with the reset and retry function near the equipment. Because it will start again suddenly when the alarm stops.
13. Make sure that the alarm is reset only after the operation signal is cut off. If the alarm is reset under the running signal, the inverter may start suddenly.
14. Do not touch the terminals of the inverter, there is high voltage on the terminals, which is very dangerous.
15. Do not change the wiring or disassemble the terminals while the power is on.

Package List:
1 x Universal Vector VFD
1 x Instruction

Note:
1. Cut off the main circuit power before