Feature(may vary by option.)

●Attencion: Non UL-Certification Listed
●Key lock available; Dual Action
●The HC102 conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches
●Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.
●Note: Call point cant work alone, need work with alarm control panel

[Call Point]




[Strobe]





Description

HC102 call pointHC102 call point

Description

  • The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional fire alarm is only used with conventional control panel, it is forbidden to be used to other system.

Operation:

  • The manual call points provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.
  • Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position , the word" ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.
  • Resetting the station is simple: insert the key, twist one quarter-turn, then open the stations front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal(non-alarm) position manually(by hand) or by closing the stations front cover, which automatically resets the switch.

Loop design and wiring:

  • The fire alarm control panel Zone wire can be connected to terminal loop(+), loop(-) unpolarized wire.
  • If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal loop(+),loop(-).

Installation:

  • Attenteion: All wiring must conform to applicable local codes, ordinances, and regulations.

Mounting indoor wall:

  • Attach mounting base to wall at 1.5 meters (59in) high
  • Connect field wiring to terminals
  • To attach product to mounting base
  • Secure product by tightening the one mounting screws in the front of the product housing

wirewire

Attention:

  • Alarm host not included, need buy seperate

itemitem
Package List:

  • 1 x Manual call point
  • 2 x Keys
  • 1 x English manual
  • Tips: Please searc B06Y2Q49T5 to get the strobe siren.

Specifications:

  • Non UL-Certification Listed
  • Operating voltage range: 9-28VDC Volts
  • Alarm resistance: 470ohm/1W
  • Operating humidity: 10% to 93% relative humidity, non-condensing
  • Operating temperature: -10℃ to 50℃ (14℉ to 122℉)
  • Dimensions (LxWxH): 140x104x45mm / 5.51"x4.09"x1.77"
  • Net Weight: 220g / 0.44lb