Feature(may vary by option.)

●Each heater can heat more than 600 chicks, each heating area is 15 to 20 square meters.
●Optional gas: natural gas, liquefied gas.
●Gas consumption: Natural gas: 0.24 m3 / h, liquefied gas: 0.18 kg / h.
●Maximum power and heating value of each heater: 2.46 kW / h, 2116 kcal / h.
●Gas pressure requirements: The gas pressure of natural gas, liquefied gas requires 3500 Pa to 5000 Pa;

[Natural gas]





Description

Notes and frequently asked questions:
1. When installing the brooder, keep the air inlet end tilted downward.
2. It is normal to have a blue flame at the beginning, which will disappear after a few minutes.
3. If the blue flame is always on the ceramic plate, please check if the air pressure is too low; if so, please debug the pressure reducing valve or booster pump.
4. If the red flame is large, the reason may be:
a. The air pressure is too high; please adjust the pressure reducing valve to the required pressure.
b. Hypoxia; please keep indoor air circulation when using this product.
c. The ceramic plate is cracked; please replace the ceramic plate.
d. Gas purity is different; the gas purity of each country is different, which may cause a relatively large flame, please match the appropriate nozzle
5. If the burning surface is uneven, please check if there are feathers on the filter.
6. This product is flameless. In the normal working process, you will only see the red burning surface without flame.
7.Please regularly check and clean up all parts of the entire system.